GF67920

Power Line Filters

Stand Alone Wall Mount

Power filters protect and facilitate power and secure communications for shielded rooms and buildings.

Download Product Data Sheet:  GF67920 Data Sheet

SPECIAL FEATURES

Filters

  • Factory pre-wired clean output lead provided through the pipe penetration
  • Low Pass filter circuits ~ passive components which includes inductors, capacitors, resistors and optional transient suppression devices
  • Manufactured and tested per applicable portions of MIL-PRF-15733
  • All circuits provided in single enclosure
  • Discharge resistors incorporated to eliminate potential shock hazard

Enclosure

  • Fabricated case of not less than 18 gauge cold rolled steel electro plated or painted Gray (Std. Paint Color)
  • Sealed with welded and soldered seams for minimum shielding effectiveness 100 dB, 14 kHz to 18 GHz
  • Threaded steel pipe penetration
  • Double knock outs provided on filter case input
  • Front cover access to input terminals
  • Mounting tab provided for easy wall mount options
FUNCTIONAL CHARACTERISTICS
  • Voltage Ratings:
    • 24-1,000 VDC
    • 120/208 VAC (50/60 Hz)
    • 277/480 VAC (50/60 Hz)
  • Voltage Drop:
    • 2% maximum at full rated unity power factor load.
  • Harmonic Distortion:
    • 4% maximum at full rated unity power factor load
  • Temperature Rating:
    • MIL-PRF-15733
  • Current Overload:
    • 140% maximum current rating
  • RF Radiation:
    • Greater than 100 dB isolation
  • Dielectric With-Standing Voltage:
    • 2,200 VDC (prior to installation of discharge resistors)
  • Insulation Resistance:
    • MIL-PRF-15733 (prior to installation of discharge resistors)
  • Insertion loss:
    • 100 dB 14 KHz to 18 GHz
    • 50/50 Ohm System
APPLICABLE SPECIFICATIONS
  • Military Specifications
    • MIL-PRF-15733 General
  • Military Test Methods
    • MIL-STD-202 Component Parts
    • MIL-STD-220 Insertion Loss
    • MIL-STD-285 Shielding Effectiveness
  • NFPA 70/2011 National Electrical Code Standards
AVAILABLE OPTIONS
  • MOV's - EMP and Surge Suppressors
  • Alternate pipe penetration locations on the enclosure available by request.
  • Voltage Indicator Lights
  • Ground Wire
  • Internal Mounting Flange