Text Box: Product Detail

Reduced Enclosure (Formerly GFP58XXX Series) EMI/RFI facility filters specified to 100 dB are used in government and commercial installations to prevent unwanted signals and interference on power lines.

Product Summary

Filters

· Enclosed filters mounted on an internal RF secure inner case

· Multi-circuit

· 100 dB or 60 dB series Insertion Loss per MIL-STD-220A over the frequency range of 14 kHz to 10 GHz with extended range buffer network

· Manufactured and tested per the applicable portions of MIL-PRF-15733

· Hermetically sealed with welded and soldered seams for shielding effectiveness

· Bleeder resistors incorporated to eliminate potential shock hazard

Enclosure

· Modified NEMA type fabricated panel of not less than 14 gauge cold rolled steel painted Gray

· RF tight inner area secured with RF gasket for 100 dB minimum shielding effectiveness, 14 kHz to 10 GHz, minimum

· Pre-wired standoffs and lugs

· Lifting ears included on heavier enclosures

· Front cover access to filters and standoffs

Construction Detail– Facility Panel

Text Box: Return To Product List
Facility Power Line Filters–
Capacitive Input

Last Updated: 1201311030

Special Features
Functional Characteristics

· Voltage Rating:
24-1,000 Vdc, 120/208 Vac (50/60, 400 Hz), 277/480 Vac (50/60 Hz)

· Voltage Drop:
2% maximum at full rated unity power factor load.

· Harmonic Distortion:
4% maximum at full rated unity power factor load

· Temperature Rating:
MIL-PRF-15733

· Current Overload:
140% maximum current rating

· RF Radiation:
Greater than 100 dB isolation

· Dielectric With-Standing Voltage:
2,200 Vdc (Prior to installation of discharge ckts)

· Insulation Resistance:
MIL-PRF-15733 (w/o discharge ckts)

· MIL-PRF-15733
General specifications for filters, military

· MIL-STD-202
Test methods for components parts, military

· MIL-STD-220
Test methods for insertion loss, military

· MIL-STD-285
Test method for shielding effectiveness

· NFPA 70/2011
National Electrical Code, standards

Applicable Specifications